calibration instrument sales worldwide

Flexim FLUXUS F608

  • Operating temperature of the transmitter: 14°F to 140°F
  • Flow channels: 2
  • Degree of protection: IP65, acc. to EN 60529
  • Explosion protection: ATEX Zone 2, Transducers: ATEX Zone 1 and 2
  • Accuracy (standard / field calibrated): 1.6% of reading +/- 0.01 m/s / 0.5% of reading +/- 0.01 m/s
  • Battery: Li-Ion, 7.2 V/4.5 Ah, > 14 hours operating time
  • Weight of Transmitter: 1.9 kg
  • Inputs and Outputs
  • Standard Version: Outputs: 2 x current, 2 x binary
  • Energy Version: Inputs: 2 x Pt 100/Pt1000; Outputs: 2 x current, 2 x binary
- Cena: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
- This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

Flexim FLUXUS F601

The Water Triple Point is the most important fixed point, the only point common to the ITS-90 and the Thermodynamic Temperature Scale. It is an essential reference point for every temperature laboratory.
  • Uncertainty 0.000070°C
  • Fifty Years of Proven Use
  • Quartz Glass and Isotopic Analysis Available

The Water Triple Point is the most important fixed point, the only point common to the ITS-90 and the Thermodynamic Temperature Scale. It is an essential reference point for every temperature laboratory. The Jarrett-Isotech cells are the best standard, all cells are not the same, accept no inferior device.

Total Confidence – The Internationally Proven Cells The Jarrett-Isotech cells have been in production since 1958. A independent comparison* in 1981 showed the first cell to be within 0.000006°C of the reference cell. The most recent international study organized by BIPM** consistently shows labs using both recent and older Jarrett-Isotech cells tightly grouped, tens of μK around the BIPM reference value.

International comparisons prove the quality of the Jarrett-Isotech Cells and are unique in the number, and history of comprehensive evaluations.

*“ Reproducibility of Some Triple Point of Water Cells”By George T. Furukawa and William R. Bigge. Temperature - Its Measurement & Control in Science & Industry Vol. 5 1982.
** Final Report on CCT-K7: Key comparison of water triple point cells.
M Stock et al 2006 Metrologia 43 03001

- Cena: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
- This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

ADM 7407

Flow velocity: (0.03 to 82)ft/s
Resolution: 0.0008 ft/s
Repeatability: 0.15% of reading ± 0.03ft/s

  • Non-invasive flow measurement for permanent installation
  • 1 or 2 flow channels
  • Unique signal processing
  • Flexible configuration of inputs and outputs
  • Enhanced status information
  • Integrated energy calculator and flow calculator
Measurement Measuring principle: transit time difference correlation principle - Volume flow: ± 1% to 3% of read. ±0.03ft/s depending on application ± 0.5% of reading ± 0.03ft/s with process calibration - Path velocity: ± 0.5% of reading ± 0.03ft/s Measurable fluids: all acoustically conductive fluids with < 10% gaseous or solid content in volume All FLEXIM transducers can be connected to the transmitter. Clamp-on flow transducers are available for a wide diameter range (0.25in to 256in) and for temperatures ranging from -22°F to 752°F (also in explosive atmosphere). The transducers have a degree of protection NEMA 4X (consult factory for NEMA 4P). You will find more information about the transducers in the corresponding specification sheets. Transmitter Housing - Weight: approx. 6.2lb - Deg. of protection: NEMA 4X - Material: Aluminium, powder coated - Dimensions: (11.3 x 7.87 x 2.78)in (WxHxD) with hinges Flow channels: 1 or 2 Explosion protection in: FM-C Cl 1,2,3 / Div 2 / Gpa-g / T4 pending Power supply: (100 to 240)VAC or (18 to 36)VDC Display: 2 x 16 characters, dot matrix, backlit Operating temperature: 14°F to 140°F Power consumption: < 15W Signal damping: (0 to 100)s, adjustable Measuring cycle: (100 to 1000)Hz (1 channel) Response time: 1s (1 channel), 70ms opt.

- Cena: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
- This e-mail address is being protected from spambots. You need JavaScript enabled to view it.