calibration instrument sales worldwide

Augstas precizitātes pārnēsājams digitālais termometrs F100

Augstas precizitātes 2-kanālu pārnēsājams digitālais termometrs F100
Precizitāte: 0,02 ° C
Mērīšanas kanāli: 2
Sensora veidi: Pt100, PT25, NTC termorezistora
Svars: 500g
Interfeiss: USB
Barošana: Baterija
Portatīvā 2-kanālu ciparu termometrs ar apgaismotu displeju. Mērīšanas precizitāti garantē visā diapazonā. Displeja izšķirtspēju 0,001 ° C.Termometrs darbojas, izmantojot 1 mA (Pt100) mērīšanas plūsmu, 0,00005°C/1°C. Maksimālais sensora kabeļa garums 100 metru (Pt100), 30 metru (SMART Pt100) kalibrēšanas dati ir iekļauti ITS90 un kompensācijas EN6071 formātos.
- Cena: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
- This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

F150

  • Accuracy: up to ±0.01°C and resolution up to 0.001°C for high quality data
  • Dual channel with four inputs, 2x PRTs and 2x thermocouples for real versatility
  • Temperature Range: -210° to 2315°C for Thermocouples, -210° to 1100°C for PRTs
  • LCD display: Channels A, B or A-B in °C, °F or K
  • Battery operation plus built-in data logging for "go anywhere" applications
  • The F150 digital thermometer incorporates two inputs for resistance thermometers (RTD) and two for thermocouples. It has been designed for maximum versatility and to help fill your needs for high accuracy single or differential measurements with any combination of thermometers.
    Temperature measurements in °C, °F and K, plus Ω or mV, are displayed on a large graphics LCD.
    Use it anywhere - you can operate F150 by battery or AC power and store your measured data to internal memory for later retrieval.
    Performance is assured with instrument accuracy of up to ±0.01°C and for best system accuracy, you can store RTD calibration data to enhance conversion of resistance to temperature. Similarly, for thermocouples you can choose one of the 10 industry standard linearisations in memory. F150 is supplied complete with calibration traceable to international standards.
    To give rapid, accurate results the F150 has been designed to store calibration data for each of your regularly used probes.

    - Cena: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
    - This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

    Siparu termometrs F200

    Augstas precizitātes 2 vai 8 kanālu ciparu termometrs F200
    2 vai 8 kanālu termometrs ar iespēju pieslēgt 3 vai 4 vadu rezistences sensoru
    Temperatūru diapazonā: no -200 ° C līdz + 850 ° C
    Precizitāte:
    F200/F201 (4 vadu ): ± 0,01 °C ± 0,01 ° C
    F201 (3 vadu ): ± 0,05 °C ± 0,05 ° C
    Svars: 1kg
    • izšķirtspēja: 0001 ° C
    • Atkārtojamība: ± 0,002 °C ± 0,002 ° C
    • Stabilitāte gadā: <0,005 oC (Pt100)
    • Temperatūras koeficients: < 0,00005 °C/ 1°C <0,00005 ° C / 1 C
    • Mērīšanas kārtējā 1 mA
    • Maksimālais sensora kabeļa garums 100 m.
    • Datu ieraksta formāts: ITS90 vai EN6071
    • Interfeiss: galvaniski izolētas RS232C
    • Darbības temperatūra: 0°C līdz 50 °C 0 C līdz 50 ° C
    • Barošana: 90 līdz 264 V 90 līdz 264 V
    • Garantija: 24 mēneši
    - Cena: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
    - This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

    F252

  • Accuracy: ±0.01°C; up to ±0.02°C with probe
  • 4 wire AC bridge for stability without recalibrating
  • User selectable resolution of up to 0.001°C or 0.0001 ohms over full range
  • Range: -200°C to +962°C depending on probe
  • 2 channels as standard with optional 4 or 6 channels expandable up to an additional 64 channels with Switchboxes
  • ASL's F252 provides high accuracy, dual channel temperature measurement with Platinum Resistance Thermometers - PRTs - and uses AC bridge technology as developed by ASL for Standards Laboratories throughout the world. Model F252 requires no regular recalibration, the AC circuit techniques eliminating thermal EMFs and drift, while providing excellent long term stability. Front panel data entry allows you to enter probe calibration data into the F252's memory, so that thermometer resistance can be accurately converted to temperature in °C, °F or K. This can be password protected to prohibit unauthorised or accidental data entry. The combination of proven technology and sophisticated microprocessor control gives you a reliable, easy to use precision instrument.

    - Cena: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
    - This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

    F500

  • Accuracy: ±0.005°C; (typically ±0.001°C at 001°C)
  • 4 wire AC bridge for stability without recalibrating
  • User selectable resolution of up to 0.001°C or 0.0001 ohms over full range
  • Range: -200°C to +962°C depending on probe
  • 2 channels as standard with optional 4 or 6 channels expandable up to an additional 64 channels with Switchboxes
  • ASL's F500 provides high accuracy, multi channel temperature measurement with Platinum Resistance Thermometers - PRTs - and uses AC bridge technology as developed by ASL for Standards Laboratories throughout the world. Model F500 requires no regular recalibration, the AC circuit techniques eliminating thermal EMFs and drift, while providing excellent long term stability. Front panel data entry allows you to enter probe calibration data into the F500's memory, so that thermometer resistance can be accurately converted to temperature in °C, °F or K. This can be password protected to prohibit unauthorised or accidental data entry. The combination of proven technology and sophisticated microprocessor control gives you a reliable, easy to use precision instrument.

    - Cena: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
    - This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

    TTI-7+

    PRT and Thermocouple Thermometer
    -200°C to 2315°C (4199°C)
    ±0.01°C (±10mK) accuracy
    Accepts Scanner Cards for up to 10 Channels of Measurement
    - 0.001°C Resolution (Pt100 Inputs)
    - PRT and Thermocouple Inputs
    - Eliminates Unwanted Thermal EMFs with Current Reversal
    - Stores 4000 Measurements
    - PC Interface and Software Included, RS232
    - 10 Hours Use from Internal Battery


    The TTI-7 is a very high accuracy multi purpose digital thermometer for both platinum resistance thermometers and thermocouples. Laboratory users will welcome the features to eliminate Thermal EMF Errors and Self Heating Errors along with provision to store the calibration data of up to 20 PRT probes. The rugged aluminum case, internal battery pack and integrated power supply ensure reliable portable field use for demanding measurement applications all at great value.

    Dual Channel Input allows a probe on Channel B to be calibrated against a standard on Channel A - directly compare any combination of PRT and Thermocouple. The TTI-7 supports ten thermocouple Types, B,C, D, E, J, K, N, R, S and T and Pt100 thermometers. Connect up to 16 sensors via the optional switchboxes, Model 954 and 958.

    - Cena: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
    - This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

    TTI-10

    - High Accuracy Handheld Thermometer
    - High Resolution, to 0.001°C
    - High Accuracy to 0.01°C
    - Perfect Standard for use with Isocal-6, Fast-Cal & Dry Blocks
    The TTI-10 is a high accuracy handheld temperature indicator with two platinum resistance thermometer inputs. The high precision makes the instrument particularly suitable as a portable reference thermometer to use alongside Isotech temperature calibrators such as the Fast-Cal, Isocal-6 and Dry Block ranges. It is also suited for high accuracy measurements in industrial and scientific applications.

    TTI-10 brings laboratory level performance of up to 10mK (0.01°C) and resolution up to 0.001°C in a portable handheld instrument. Battery life is typically 20 hours from a 9V PP3 battery and a protective rubber boot offers protection in field use.

    The instrument can capture the minimum, maximum and average values over up to 4000 measurements with a logging rate selectable in the range of 1 second to 30 minutes.

    The TTI-10 has an easy to use “learning calibration mode” that allows the TTI-10 to be system calibrated with a Platinum Resistance Thermometer simply by comparing it to a calibrated standard thermometer, no need to calculate coefficients or data, simply enter the reference probe temperature or temperatures and the TTI-10 does the work for you.

    A USB interface allows connection to Isotech Cal Notepad software with its charting and logging features.

    TTI-10 supports Isotech Semi Standard Platinum Resistance probes with system uncertainties (probe and instrument) as low as 20mK. We recommend the 935-14-61 and 935-14-16 probes detailed below and have special calibration deals available. Other probes and ranges are available, refer to Semi Standards – Platinum Resistance Thermometers

    - Cena: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
    - This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

    TTI-22

    -250°C to 960°C

    5 to 10 times the performance of comparably priced instruments!

    - ±0.001°C (1mK) accuracy
    - 0.0001°C (0.00004Ω) resolution
    - contains both RS232 and Ethernet ports
    - 10 Hours Use from 2 AA batteries

    Quite simply the Isotech TTI-22 High Accuracy Thermometer sets new standards in the price to performance ratio for industrial and secondary resistance thermometry. If you need high accuracy at an affordable price you have to look at the TTI-22.

    The TTI-22 has an accuracy of 0.001°C and a resolution of 0.0001°C (0.00004 Ohms). It has two input channels, is lightweight (1.8kg) and will operate for more than 10 hours from two small AA cells. It has both RS232 and Ethernet ports.

    Simple to use, supporting both Industrial 100 Ohm probe and SPRTs to ITS-90, 25.5 and 100 Ohm. Up to 30 probe calibrations can be stored along with the calibration expiry date so the instrument can warn when the calibration time has been exceeded.

    Built in statistics calculation can show you both the measured and average values along with the standard deviation over previous measurements.

    The Isotech TTI-22 is ideal as a reference standard alongside liquid calibration baths, for the smallest uncertainty calibration with Dry Blocks or for demanding stand alone measurement applications.

    Previously this level of performance was confined to specialist laboratories with expensive thermometry bridges; TTI-22 delivers 5 to 10 times the performance of comparably priced instruments.

    - Cena: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
    - This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

    MicroK

    The new microK family of precision thermometers set new world standards for accuracy and stability. Designed for a wide range of high accuracy industrial and scientific calibration applications, the instrument uses a completely new measurement technique to achieve accuracies better than 0.1 parts per million (ppm) - equivalent to 0.0001°C - when used with a standard platinum resistance thermometer (SPRT).
    - Accuracy ±0.1ppm
    - Zero drift for PRTs
    - PRT, thermocouple and thermistor sensing
    - <2 second measurement time
    - Keep-warm currents
    - 0-10mA sensor current
    - Touch screen

    The new microK family of precision thermometers set new world standards for accuracy and stability. Designed for a wide range of high accuracy industrial and scientific calibration applications, the instrument uses a completely new measurement technique to achieve accuracies better than 0.1 parts per million (ppm) - equivalent to 0.0001°C - when used with a standard platinum resistance thermometer (SPRT).

    When used with a 0°C cold junction reference unit, or by measuring the junction temperature with a PRT on another channel the instrument is capable of low uncertainty precision thermocouple measurements, with a voltage uncertainty of just 0.25μV, equivalent to 0.01°C with a Platinum / Gold Thermocouple at 1000°C.

    The microK range consists of four instruments offering a choice of measurement uncertainty from 0.1 to 0.8ppm, equivalent to 0.1mK to 0.8mK over the whole range of an SPRT with an Ro >2.5Ω.

    The instruments in the microK range offer performance characteristics and features which are simply not available elsewhere. Comparable instruments available internationally do not achieve the same accuracy or stability (zero drift characteristics with SPRT measurements are not obtainable in any other instrument), other instruments do not support the same variety of sensors, and offer considerably less operational features. The microK family uses solid state construction with no potentiometers or relays which ensures long term reliability and low cost of ownership, a feature of growing international importance.

    - Cena: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
    - This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

    MilliK

    - Range: -270°C to 1820°C (3308°F)
    - Accuracy: ±0.005°C (±5mK) full range for PRTS
    - Resolution: 0.0001°C (0.1mK)
    - SPRT/PRT, Thermocouple, Thermistor and 4-20mA Inputs
    - Full color graphical display
    - Store up to 180 days of measurements
    - Can control Isotech calibration baths
    - 4 AA batteries or universal power supply

    The milliK Precision Thermometer from Isotech sets a new standard for the high accuracy measurement and calibration of Platinum Resistance Thermometers, Thermistors, Thermocouple and Process Instrumentation (4-20mA) over the range -270°C to 1820°C.
    In addition to low uncertainty measurements from Reference Standards and Industrial sensors, the milliK can control Isotech temperature sources, sequencing through a programmable list of temperature set points and log data to internal memory or a USB drive. The milliK forms the hub of a measurement system, reading SPRTs, RTDs, Thermistors, Thermocouples and 4 - 20mA current inputs with the option to control calibration baths and log readings.

    - Cena: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
    - This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

    Temperatūras mērierīce C100

    Digitālā temperatūras mērierīce, C100 (Pt100 termometri)
    • Temperatūras diapazons ir -200 ° C līdz 500 ° C
    • Mērījumu kļūda: ± 0,1 ° C mērījumu diapazonā no -100 ° C līdz 200 ° C ± 0,2 ° C vai mērīšanas diapazons
    • izšķirtspēja: 0,01 ° C
    • Svars 400 g
      1 Mērīšanas kanāls
    • Temperatūras sensori: Pt100 (4 vadi)
    • Mērvienības: ° C, F
    • Opcijas: nulle, Min, Max, Average, datums, laiks / Auto OFF, CAL, displeja apgaismojums
    • Barošana: 4x1, 5V (AA baterijām)
    • Darbības temperatūra 0 C līdz 50 ° C
    • Garantija 24 mēneši
    - Cena: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
    - This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

    Temperatūras mērierīce C110

    <
    Digitālā temperatūras mērierīce, C110 (Pt100 termometri)
    • Temperatūras diapazons ir -200 ° C līdz 1770 ° C
    • mērījumu kļūda: ± 0,1 ° C mērījumu diapazonā no -100 ° C līdz 200 ° C.
    • Termopāri (K, J, N, E, R, S, T) ± 0,5 ° ± 0,2% no joslas (bez sensors)
    • izšķirtspēja: Pt100: 0,01 ° C
    • Svars: 400 grami
      2 mērīšanas kanāli
    • Kanāli: PT 100 (4 vadi)
    • Mērvienības: ° C, F
    • Opcijas: nulle, Min, Max, Average, datums, laiks / Auto OFF, CAL, displeja fona apgaismojums
    • Barošana: 4x1, 5V (AA baterijām)
    • Darbības temperatūra: 0 ° C līdz 50 ° C
    • Garantija: 24 mēneši
    - Cena: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
    - This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

    Temperatūras mērierīce C120

    Digitālā temperatūras mērierīce, C120
    • Temperatūras diapazons ir -200 ° C līdz 1770 ° C
    • Mērījumu kļūda: ± 0,5 ° C + 0,2% no joslā (bez sensors)
    • Izšķirtspēja: 0,1 °C
    • Svars: 400g
      2 mērīšanas kanāli
    • Temperatūras sensoru: K, J, N, E, R, S, T
    • Mērvienības: ° C, F
    • Opcijas: nulle, Min, Max, Average, datums, laiks / Auto OFF, CAL, displeja fona
    • Barošana: 4x1, 5V (AA baterijām)
    • Darbības temperatūra: 0 ° C līdz 50 ° C
    • Garantija: 24 mēneši
    - Cena: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
    - This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

    Martel BetaProbe

    .Low total cost of ownership (TCO) compared to L-I-G thermometers

  • High accuracy (± 0.06˚C)
  • High resolution (0.001˚C)
  • Hazardous area use rating
  • Fast response
  • Data logging with optional BetaLOG™ TI software
  • Temperature trend indicator
  • Rugged and reliable
  • EFI/RFI standard compliant
  • Long battery life
  • User configurable features
  • Compact and lightweight

  • A single BetaProbe TI high precision digital thermometer can
    replace many liquid-in-glass (l-i-g) thermometers. It can also serve as
    a reference standard for other types of digital or analog temperature
    indicators. Plus, intrinsically safe certification means it can be used
    virtually anywhere.
    The integral 3/16" (5 mm) diameter probe houses a quick response
    thin film sensor for quickly acquiring highly accurate readings using
    minimal insertion depth. The integral probe also rotates through
    90° for any angle reading of the display.

    - Cena: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
    - This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

    Resistance Bridge Calibrator RBC100M & RBC400


    Calibrate thermometry bridges quickly,
    simply and in-house

  • Calibrate ac and dc thermometry bridges
  • High accuracy - better than 0.1 ppm at 100 Ohms
  • Patented design licensed from IRL
  • Windows application for full analysis and reportin
  • The Resistance Bridge Calibrators employ a powerful combinatorial calibration method and a patented resistor network. The network generates 35 different four-terminal resistances from various series and parallel combinations of just four resistors. Analysing the combination measurements, combined with knowledge of the interrelationships between them, enables a complete calibration of your resistance bridge.

    - Cena: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
    - This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

    Kontakti

    SIA "Tek Know Baltic"
    Ceriņu 10, LV-1029
    Riga, Latvia

    Reģ. Nr. 40003921905
    PVN Nr. LV40003921905
    Rēķins IBAN: LV12HABA0551016555179
    Swedbank, kods HABALV22

    E-mail: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
    Tel.: +371 29174006,
    +371 67327226
    Fax: +371 67327226